User's Manual

Table Of Contents
Abbreviated (All–inclusive) Acceptance Tests – continued
4-10 1X SC 4812T Lite BTS Optimization/ATP FEB 2005
PRELIMINARY
Table 4-4: All RX Acceptance Test Procedure
n ActionStep
5 Verify that the correct Channel Number for the selected carrier is shown in the Carrier #
Channels Box.
If it is not, obtain the latest bts–#.cdf (or bts–#.necf) and cbsc–#.CDF Files from the CBSC.
NOTE
If necessary, the correct Channel Number may be manually entered into the Carrier # Channels
Box.
6 Select the appropriate RX Branch (BOTH, MAIN, or DIVersity) in the Pull–down Menu.
7 In the Rate Set Box, select the appropriate Data Rate (1=9600, 2=14400, 3=9600 1X) from the
Pull–down Menu.
NOTE
The Rate Set Selection of 1 is only available if non–1X Cards are selected for the test.
The Rate Set Selection of 3 is only available if 1X Cards are selected for the test.
8 Enter the Channel Elements to be tested for the RX ATP in the Channel Element(s) Box.
By default, all Channel Elements are specified.
The Channel Element Numbers are 0.based; that is the first Channel Element is 0.
NOTE
Use one of the following methods to enter more than one Channel Element:
Enter non–sequential Channel Elements separated by a comma and no spaces (for example;
0,5,15).
Enter a range of sequential Channel Elements by typing the first and last Channel Elements
separated by two periods (for example; 0..15).
9 Click OK to display a Status Bar followed by a Directions Pop–up Window.
10 Follow Cable Connection Directions as they are displayed, and click the Continue Button to
begin testing.
When the ATP Process is completed, results will be displayed in the Status Report Window.
11 Click either the Save Results Button or the Dismiss Button.
* IMPORTANT
If Dismiss is used, the test results will not be saved in the Test Report File.
4