User's Manual
Table Of Contents
- Chapter 1: Introduction
- Chapter 2: Preparatory Tasks
- Chapter 3: Optimization/Calibration
- Introduction to Optimization and Calibration
- Preparing the LMF
- Overview of Packet BTS Files
- LMF Features and Installation Requirements
- LMF File Structure Overview
- LMF Home Directory
- NECF Filename Conventions and Directory Location
- LMF Installation and Update Procedures
- Copy BTS and CBSC CDF (or NECF) Files to the LMF Computer
- Creating a Named HyperTerminal Connection for MMI Communication
- Span Lines - Interface and Isolation
- LMF to BTS Connection
- Switching the Active LAN - LMF I/O Panel 10Base-2 LAN Connection
BTS Equipment Identification – continued
FEB 2005 1X SC 4812T Lite BTS Optimization/ATP 1-17
PRELIMINARY
A Logical BTS can consist of up to four SC 4812T Frames. When the
LMF is connected to Frame 1 of a Logical BTS, you can access all
devices in all of the frames that make up the Logical BTS. A Logical BTS
requires a CDF/NECF File that includes Equipage Information for all of
the Logical BTS Frames and their devices and a CBSC File that includes
Channel Data for all of the Logical BTS Frames.
Logical BTS Numbering
The first BTS Frame of a Logical BTS has a –1 Suffix (e.g., BTS–812–1).
Other frames of the Logical BTS are numbered with Suffixes, –101, –201,
and –301 (e. g. BTS–812–201). When you log into a BTS, a FRAME
TAB is displayed for each BTS Frame. If there is only one frame for the
BTS, there is only one Tab (e.g., FRAME–282–1) for BTS–282.
If a Logical BTS has more than one frame, there is a separate FRAME
TAB for each BTS Frame (e.g. FRAME–438–1, FRAME–438–101, and
FRAME–438–201 for a BTS–438 that has three frames). If an RFDS is
included in the CDF/NECF File, an RFDS Tab (e.g., RFDS–438–1) is
displayed.
Actions (e.g., ATP Tests) can be initiated for selected devices in one or
more frames of a Logical BTS. Refer to the Select Devices Help Screen
for information on how to select devices.
SCCP Cage Card/Module Device ID Numbers
All cards/modules/boards in the frames at a single site, assigned to a
single BTS Number, are also identified with unique Device ID Numbers
dependent upon the BTS Frame ID Number in which they are located.
Refer to Table 1-3 and Table 1-4 and Figure 1-8 for specific Device ID
Numbers.
Table 1-3: SCCP Cage/Cage Card/Module Device ID Numbers (Top Shelf)
Card/Module ID Number (Left to Right)
Frame
#
Power
(PS–1)
Power
(PS–2)
AMR–1 GLI3–1 MCC BBX
BBX–R
(Optional)
MPC/
EMPC–1
1 – – 1 1 1 2 1 2 3 R1 –
101 – – 101 101 101 102 101 102 103 R101 –
201 – – 201 201 201 202 201 202 203 R201 –
301 – – 301 301 301 302 301 302 303 R301 –
Table 1-4: SCCP Cage/Cage Card/Module Device ID Numbers (Bottom Shelf)
Card/Module ID Number (Left to Right)
Frame
#
HSO CSM –1 CSM –2 CCD A CCD B AMR–2 GLI3–2 MCC BBX SW
MPC/
EMPC–2
1 – 1 2 – – – 2 2 3 4 4 5 6 – –
101 – 101 102 – – – 102 102 103 104 104 105 106 – –
201 – 201 202 – – – 202 202 203 204 204 205 206 – –
301 – 301 302 – – – 302 302 303 304 304 305 306 – –
1