User's Manual

Required Test Equipment and Software continued
PRELIMINARY
1X SCt4812ET Lite BTS Optimization/ATP
08/01/2001
1-8
Model SLN2006A MMI interface kit
S Motorola Model TRN9666A null modem board. Connectors on
opposite sides of the board must be used as this performs a null
modem transformation between cables. This board can be used for
25pin to 8pin, 25pin to 25pin, and 10pin to 10pin conversions.
S Motorola 3009786R01 MMI cable or equivalent; used to interface
the CDMA LMF serial port connection to the GLI, CSM, ETIB board,
and module debug serial ports.
Communications system analyzer CDMA/analog
The following communications system analyzers are supported by the
LMF:
S Motorola CyberTest
S Advantest R3465 Analyzer with R3561L Signal Generator
S Hewlett Packard Model HP 8921A/600 Analyzer including 83203B
CDMA Interface, manual control system card, and 83236A/B PCS
Interface for 1900 MHz BTSs.
S Hewlett Packard Model HP 8935 Analyzer
or a combination of test equipment supported by the CDMA LMF and
used during optimization and testing of the RF communications portion
of BTS equipment.
The analyzer provides the following functions:
S Frequency counter.
S Deviation meter.
S RF power meter (average and code domain).
S RF signal generator (capable of DSAT/CDMA modulation).
S Audio signal generator.
S AC voltmeter (with 600ohm balanced audio input and high
impedance input mode).
S Noise measurement meter.
S CMessage filter.
S Spectrum analyzer.
S CDMA code domain analyzer.
GPIB cables
Hewlett Packard 10833A or equivalent; one or two meters long, used to
interconnect test equipment and CDMA LMF terminal.
Power meter
S Hewlett Packard Model HP437B with HP8481A power sensor capable
of measuring from 30 dBm to 20 dBm,
or