User's Manual

Test Set Calibration continued
PRELIMINARY
08/01/2001
3-63
1X SCt4812ET Lite BTS Optimization/ATP
Setting TX Coupler Loss Value
If an inservice TX coupler is installed the coupler loss (e.g., 30 dB)
must be manually entered so it will be included in the LMF TX
calibration and audit calculations.
Prerequisites
S Logged into the BTS
Table 3-30: Setting TX Coupler Loss Values
Step Action
1 Click on the Util menu.
2 Select Edit > TX Coupler Loss. A data entry popup window will appear.
3 Click in the Loss (dBm) column for each carrier that has a coupler and enter the appropriate value.
4 To edit existing values click in the data box to be changed and change the value.
5 Click on the Save button to save displayed values.
6 Click on the Dismiss button to exit the window. Values that were entered/changed after the Save
button was used will not be saved.
NOTE
S The InService Calibration check box in the Options > LMF Options > BTS Options tab must
checked before entered TX coupler loss values will be used by the TX calibration and audit
functions.
S Entered values will be used by the LMF as soon as they are saved. You do not have to logout and
login.
3