User Manual
GPIB68P09255A57-2
Aug 2002
SC4812ET Optimization/ATP Manual Software Release R16.1.x.x
PRELIMINARY
I-7
Figure I-4: HP8921A and HP83236A/B
Preset
Cursor ControlShift
Local
Advantest R3465 GPIB Address
Table I-6 describes the steps to verify and, if necessary, change the GPIB
address for the Advantest R3465.
NOTE
This procedure assumes that the test equipment is set up and
ready for testing.
Table I-6: Verify and/or Change Advantest R3465 GPIB Address
Step Action
1 To verify that the GPIB address is set correctly, perform the following procedure:
- Press SHIFT then PRESET (see Figure I-5).
- Press LCL.
- Press the GPIB and Others CRT menu key to view the current address.
2 If the current GPIB address is not set to 18, perform the following to change it:
- Turn the vernier knob as required to select 18.
- Press the vernier knob to set the address.
3 To return to normal operation, press Shift and Preset.