User Manual

GPIB
68P09255A57-2
Aug 2002
SC4812ET Optimization/ATP Manual Software Release R16.1.x.x
PRELIMINARY
I-6
Setting HP8921A and HP83236A/B GPIB Address
Follow the procedure in Table I-5 to verify and, if necessary, change the
HP8921A HP83236A GPIB addresses.
NOTE
This procedure assumes that the test equipment is set up and
ready for testing.
Table I-5: Verify and/or Change HP8921A and HP83236A GPIB Addresses
Step Action
1 To verify that the GPIB addresses are set correctly, press Shift and LOCAL on the HP8921A (see
Figure I-4). The current HP-IB address is displayed at the top of the screen.
NOTE
HP-IB is the same as GPIB.
2 If the current HP-IB address is not set to 18, perform the following to change it:
- Turn the Cursor Control knob to move the cursor to More and press the knob to select the field.
- Turn the Cursor Control knob to move the cursor to I/O Config and press the knob to select the
field.
- Turn the Cursor Control knob to move the cursor to Adrs and press the knob to select the field.
- Turn the Cursor Control knob to change the HP-IB address to 18 and press the knob to set the
address.
- Press Shift and Preset to return to normal operation.
3 To set the HP83236A (or B) PCS Interface GPIB address=19, set the dip switches as follows:
- A1=1, A2=1, A3=0, A4=0, A5=1, HP-IB/Ser = 1