User Manual

Intra-Cabinet Cabling
68P09255A57-2
Aug 2002
SC4812ET Optimization/ATP Manual Software Release R16.1.x.x
PRELIMINARY
H-12
LPAC Cabling
The LPAC module provides the communication interface from the ETIB
and C-CCP to the LPA through the trunking backplane. The LPAC
interface board is contained in a protective housing which is mounted on
the RF cabinet frame behind the ETIB module. See Figure H-3,
Figure H-8 and Figure H-9 for connecting cables and connector
locations.
The LPAC is located internally to the frame as shown in Figure H-1.
Figure H-8: LPAC Interface Board Connectors and Attaching Cable Numbers
NOTE: The LPAC is Located
Behind the ETIB Module
LPAC INTERFACE
BOARD
LPA 1A, 1B 1C, 1D
RIBBON CABLE
3086566H01
LPA 2A, 2B 2C, 2D
RIBBON CABLE
3086566H01
LPA 3A, 3B 3C, 3D
RIBBON CABLE
3086566H01
LPA 4A, 4B 4C, 4D
RIBBON CABLE
3086566H01
LPA-1
LPA-2
LPA-3
LPA-4
FRONT
TX
OUT1
TX
OUT2
TX
OUT3
TX IN 3
TX
IN2
TX IN
1
LPA BACKPLANE
1, 2, 3, & 4
Cable # 3086566H01
(4 Connections each Side)
ALARM RIBBON
CABLE TO ETIB
3086655H02
RIBBON CABLE TO
C-CCP BACKPLANE
3064794A03
FW00702