User Manual
Test Equipment Setup68P09255A57-2
Aug 2002
SC4812ET Optimization/ATP Manual Software Release R16.1.x.x
PRELIMINARY
F-7
Pretest Setup for HP8921A
Before the HP8921A CDMA analyzer is used for LMF controlled testing
it must be set up correctly for automatic testing.
Table F-5: Pretest Setup for HP8921A
Step Action
1 Unplug the memory card if it is plugged in.
2 Press the CURSOR CONTROL knob.
3 Position the cursor at IO CONFIG (under To Screen and More) and select it.
4 Select Mode and set for Talk&Lstn.
Pretest Setup for HP8935
Before the HP8935 CDMA analyzer is used for LMF controlled testing
it must be set up correctly for automatic testing.
Table F-6: Pretest Setup for HP8935
Step Action
1 Unplug the memory card if it is plugged in.
2 Press the Shift button and then press the I/O Config button.
3 Press the Push to Select knob.
4 Position the cursor at IO CONFIG and select it.
5 Select Mode and set for Talk&Lstn.
Advantest R3465 Connection
The following diagram depicts the rear panels of the Advantest test
equipment as configured to perform automatic tests. All test equipment
is controlled by the LMF via an IEEE-488/GPIB bus. The LMF expects
each piece of test equipment to have a factory-set GPIB address (refer to
Table F-7). If there is a communications problem between the LMF and
any piece of test equipment, you should verify that the GPIB addresses
have been set correctly and that the GPIB cables are firmly connected to
the test equipment.
Figure F-3 shows the connections when not using an external 10 MHz
Rubidium reference.
F