User Manual
Adjusting for loss68P09255A57-2
Aug 2002
SC4812ET Optimization/ATP Manual Software Release R16.1.x.x
PRELIMINARY
3-93
Table 3-51: RFDS TSIC Calibration Channel Frequencies
System Channel Calibration Points
800 MHz (A and B) 341 and 682
1.9 GHz 408 and 791
WARNING
Before installing any test equipment directly to any TX OUT
connector, verify that there are no CDMA channels keyed.
Failure to do so can result in serious personal injury and/or
equipment damage.
RFDS Calibration Procedure
Prerequisites
Test equipment has been selected.
Test equipment and test cables have been calibrated.
TX calibration has been performed and BLO data has been
downloaded to the BBXs.
Test equipment and test cables are connected for TX calibration.
Antenna map data has been entered for the site.
BBXs are INS_TEST.
Follow the procedure in Table 3-52 to perform RFDS calibration.
3