User Manual
Adjusting for loss68P09255A57-2
Aug 2002
SC4812ET Optimization/ATP Manual Software Release R16.1.x.x
PRELIMINARY
3-89
Table 3-46: RFDS Parameter Settings
Step Action
8b - Click on TSU in the BTS menu bar, and select Status TSU from the pull-down menu.
-- A status report is displayed showing the software version number for the TSIC and SUA.
8c
- Click OK to close the status report window.
* IMPORTANT
If the LMF displays an error message, check the following:
Ensure AMR cable is correctly connected from the BTS to the RFDS.
Verify RFDS has power.
Verify RFDS status LED is green.
Verify entries in RFDS fields of the bts-#.cdf file are correct (refer to step 1).
Status the MGLI and ensure it is communicating (by Ethernet) with the LMF, and is in the proper
state (INS_ACT (bright green)).
RFDS TSU NAM Programming
The Number Assignment Module (NAM) information needs to be
programmed into the TSU before it can receive and process test calls, or
be used for any type of RFDS test. The RFDS TSU NAM must be
programmed with the appropriate system parameters and phone number
during hardware installation. The TSU phone and TSU MSI must be
recorded for each BTS used for OMC-R RFDS software configuration.
NOTE
The user will only need to program the NAM for the initial
installation of the RFDS.
Explanation of Parameters Used When Programming the TSU NAM
Table 3-47 defines the parameters used when editing the tsu.nam file.
Table 3-47: Definition of Parameters
Access Overload Code
Slot Index
System ID
Network ID
These parameters are obtained from the switch.
Primary Channel A
Primary Channel B
Secondary Channel A
Secondary Channel B
These parameters are the channels which are to be used in operation
of the system.
Lock Code
Security Code
Service Level
Station Class Mark
Do NOT change.
3