User Manual

Adjusting for loss68P09255A57-2
Aug 2002
SC4812ET Optimization/ATP Manual Software Release R16.1.x.x
PRELIMINARY
3-83
Test equipment and test cables are calibrated and connected for TX
BLO calibration.
LMF is logged into the BTS.
Follow the procedure in Table 3-43 to perform the BTS TX Path Audit
test.
Table 3-43: BTS TX Path Audit
Step Action
1 Select the BBX(s) to be audited.
NOTE
If STANDARD or CDF is selected for Test Pattern, then at least one MCC must be also selected.
2 From the Tests menu, select TX>TX Audit.
3 Select the appropriate carrier(s) displayed in the Channels/Carrier pick list.
Press and hold the <Shift> or <Ctrl> key to select multiple items.
4 Type the appropriate channel number in the Carrier n Channels box.
5 Select Verify BLO (default) or Single-sided BLO.
NOTE
Single-sided BLO is only used when checking non-redundant transceivers.
6 From the Test Pattern pick list, select a test pattern.
NOTE
Selecting PILOT (default) performs tests using a pilot signal only.
Selecting STANDARD performs tests using pilot, synch, paging and six traffic channels. This
requires an MCC to be selected.
Selecting CDFPILOT performs tests using the CDF value for pilot gain and IS-97 gain values
for all the other channels included in the Standard pattern setting (paging, synch, and six
traffic). Using this pattern setting requires the selection of both a BBX and at least one MCC.
Selecting CDF performs tests using pilot, synch, paging and six traffic channels, however, the
gain for the channel elements is specified in the CDF file.
7 Click on OK.
8 Follow the cable connection directions as they are displayed.
A status report window displays the test results.
9 Click on Save Results or Dismiss to close the status report window.