User's Manual Part 1

ATP Tools and Materials – continued
DRAFT
1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU
Jun 2004
1-18
Model SLN2006A MMI Interface Kit
S Motorola Model TRN9666A null modem board. Connectors on
opposite sides of the board must be used as this performs a null
modem transformation between cables. This board can be used for
10–pin to 8–pin, 25–pin to 25–pin and 10–pin to 10–pin conversions.
S Motorola 30–09786R01 MMI cable or equivalent; used to interface
the LMF serial port connection to GLI, CSA and cCLPA debug serial
ports.
CDMA2000 1X signal generators
S Agilent E4432B signal generator (required for use with Agilent
E4406A when performing Frame Erasure Rate acceptance testing)
or
S Advantest R3562 signal generator (required for use with Advantest
R3267 when performing Frame Erasure Rate acceptance testing)
Power meter
S Hewlett Packard Model HP437B with HP8481A power sensor capable
of measuring from –30 dBm to 20 dBm
or
S Gigatronics 8542B power meter
Timing Reference Cables
S Two BNC–male to BNC–male RG316 cables; 3.04 m. (10 ft.) long,
Two BNC–male to BNC–male RG316 cables; 0.61 m. (2 ft.) long
with Two BNC “T” connectors, used to interconnect the
Communications Analyzer to CSA front panel timing references in the
BTS.
RF Attenuators
S 30 dB Fixed in–line attenuators, 150 W (Narda 769–30) used in
conjunction with calibration of test cables.
S 50 dB attenuator for connection to 30 dB directional coupler
Misc. Components (RF Adaptors, Loads, Cables, etc.)
S As required to interface test cables and BTS equipment and for
various test set ups. Should include at least (2) 50–Ohm loads (type
N) for calibration, (1) RF short, (2) RF cables, (1) GPIB Box, and (1)
ethernet cable.
RF Load
S 150W non–radiating RF load; used (as required) to provide dummy
RF loading during BTS transmit tests.
High–Impedance Conductive Wrist Strap
S Motorola Model 42–80385A59; used to prevent damage from
Electrostatic Discharge (ESD) when handling or working with
modules.