User's Manual Part 1

Compact Combined Linear Power Amplifier Installation – continued
Jun 2004
4-17
1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU
DRAFT
BTS Data Cable Connection
Procedure
Once the Data Cable has been built, follow the procedure in Table 4-11
to connect the BTS Data cable to the cCLPA.
Table 4-11: Procedure to Attach BTS Data Cable to cCLPA
Step Action
1 If not already performed, remove 8 screws securing I/O Panel cover.
2 Route BTS Data cable to the cCLPA. See Figure 4-12.
3 Mate Data cable RJ45 plug to I/O Board RJ45 socket. See Figure 4-12. Table 4-10 identifies the data
cable wiring.
4 If there are two cCLPAs in use, bundle cables together and place ferrite core around cables. Ensure
that the cables are not being pinched before closing and latching the ferrite core.
5 Slide ferrite core as close to the BTS connectors as possible without causing stress. Use a tie–wrap on
the ferrite core side away from the connector. The tie–wrap holds the ferrite core in place
6 Install I/O Panel Cover and secure using 8 screws. Torque screws to 2.3 N–M (20 in–lbs).
4