User's Manual Part 1
Compact Combined Linear Power Amplifier Installation – continued
DRAFT
1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU
Jun 2004
4-16
Table 4-9: Data Cable Description and Part Number
Cable Qty. Part Number Description
G 1 Customer
Supplied
RJ45 cable for BTS to cCLPA
1 7687717T02 Ferrite, clip–on core
Data Cable Wiring Information
Table 4-10 lists the wiring information required to manufacture the
CBIO–to–cCLPA Data Cable. Figure 4-11 shows the location of Pin 1
on the RJ45 connector.
Table 4-10: Data Cable Wiring Scheme
CBIO Signal Name Wire Color RJ45 Pin
Outs
cCLPA Signal Name
Txx_ACT_P White/Orange 1 CLPA_485_TX_ACT_P
Txx_ACT_N Orange 2 CLPA_485_TX_ACT_N
CLPA_x_ADDR White/Green 3 CLPA_485_ADD_0
RxD_x_P Blue 4 CLPA_485_TX_A_P
RxD_x_N White/Blue 5 CLPA_485_TX_A_N
GROUND Green 6 GROUND
TxD_P White/Brown 7 CLPA_485_RX_A_P
TxD_N Brown 8 CLPA_485_RX_A_N
Figure 4-11: CBIO–to–cCLPA Data Cable RJ45
Connector
Pin 1
Wires inserted
in this end
4