Test Equipment Connection, Testing, and Control – continued
B-22 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU Jun 2004
DRAFT
Table B-16: Pretest Setup for HP 8921A
Step Action
1 Unplug the memory card if it is plugged in.
2 Press the CURSOR CONTROL knob.
3 Position the cursor at IO CONFIG (under To Screen and More) and select it.
4 Select Mode and set for Talk&Lstn.
Pretest Setup for Agilent 8935
Before the Agilent 8935 analyzer is used for WinLMF controlled testing
it must be set up correctly for automatic testing. Perform the procedure
in Table B-17.
Table B-17: Pretest Setup for Agilent 8935
Step Action
1 Unplug the memory card if it is plugged in.
2 Press the Shift button and then press the I/O Config button.
3 Press the Push to Select knob.
4 Position the cursor at IO CONFIG and select it.
5 Select Mode and set for Talk&Lstn.
Advantest R3465 Connection
The following diagram depicts the rear panels of the Advantest R3465
test equipment as configured to perform automatic tests. All test
equipment is controlled by the WinLMF via an IEEE–488/GPIB bus.
The WinLMF expects each piece of test equipment to have a factory-set
GPIB address (refer to Table B-9 and Figure B-9). If there is a
communications problem between the WinLMF and any piece of test
equipment, verify that the GPIB addresses have been set correctly and
that the GPIB cables are firmly connected to the test equipment.
Figure B-15 shows the connections when not using an external 10 MHz
Rubidium reference.
B