User's Manual

Test Equipment Connection, Testing, and Control – continued
Jun 2004 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU B-21
DRAFT
HP 8921A with PCS Interface
System Connectivity Test
Follow the steps outlined in Table B-15 to verify that the connections
between the PCS Interface and the HP 8921A are correct and cables are
intact. The software also performs basic functionality checks of each
instrument.
Disconnect other GPIB devices, especially system
controllers, from the system before running the
connectivity software.
NOTE
Table B-15: System Connectivity
Step Action
NOTE
Perform this procedure after test equipment has been allowed to warm–up and stabilize for a
minimum of 60 minutes.
1 Insert HP 83236A Manual Control/System card into memory card slot.
2 Press the [PRESET] pushbutton.
3 Press the Screen Control [TESTS] pushbutton to display the “Tests” Main Menu screen.
4 Position the cursor at Select Procedure Location and select it by pressing the cursor control knob. In
the Choices selection box, select Card.
5 Position the cursor at Select Procedure Filename and select it by pressing the cursor control knob. In
the Choices selection box, select SYS_CONN.
6 Position the cursor at RUN TEST and select it. The software will provide operator prompts through
completion of the connectivity setup.
7 Do the following when the test is complete,
S position cursor on STOP TEST and select it
S OR press the [K5] pushbutton.
8 To return to the main menu, press the [K5] pushbutton.
9 Press the [PRESET] pushbutton.
Pretest Setup for HP 8921A
Before the HP 8921A CDMA analyzer is used for WinLMF–controlled
testing it must be set up correctly for automatic testing. Perform the
procedure in Table B-16.
B