User's Manual

MCC–DO Tests – continued
DRAFT
1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU JUN 2004
A-10
S Agilent Signal Studio – 1xEV Reverse Link” (requires installation of
”Agilent IO Libraries” application)
S Agilent E4432B Signal Generator with option 404
Follow the procedure in Table A-5 to test the MCC–DO Packet Error
Rate.
Table A-5: Procedure to Test MCC–DO Packet Error Rate
Step Action
1 Click the BBX(s) on DO carrier to be tested.
2 On the menu, click the EvDO Tests > TX>Start Manual Tx ATP.
3 Select the appropriate carrier from the Sector/Carrier list.
4 Click the OK button.
A status report window is displayed. Test results are displayed in the window.
5 Connect the lap top computer to the Agilent E4432B Signal Generator and run the Agilent Signal
Studio – 1x EV Reverse Link application.
table continued on next page