User's Manual

Bay Level Offset Calibration68P09258A31–A
Oct 2003
1X SCt 4812T BTS Optimization/ATP
3-91
Test Pattern Drop-down Pick List
The Tests > TX > TX Calibration... menu window has a Test Pattern
pull–down menu. This menu has the following choices:
S Pilot (default) – performs tests using a pilot signal only. This pattern
should be used when running in–service tests. It only requires a BBX
to do the test.
S Standard – performs the tests using pilot, synch, paging and six
traffic channels. This pattern should be used on all non–in–service
tests. Standard requires a BBX and an MCC. Standard uses gain
values specified by the IS97 standard.
S CDFPilot –performs the tests using the pilot signal, however, the gain
is specified in the CDF file. Advanced users may use CDFPilot to
generate a Pilot pattern using the value specified by the PilotGain
parameter in the CDF file instead of a pre–determined value.
S CDF – performs the tests using pilot, synch, paging and six traffic
channels, however, the gain for the channel elements is specified in
the CDF file. Advanced users may use CDF to generate a standard
pattern. Instead of using the values specified by IS97, the settings for
the following CDF parameters are used:
PilotGain
PchGain
SchGain
NomGain1Way
Set-up for TX Calibration
The workaround in Table 3-36 allows the user to manually set the BLO
limits to ensure that the redundant BBX BLO test does not fail due to the
preset offset being incorrectly set for the frame under test. A future LMF
release will correct this problem.
Table 3-36: Initial Set-up for TX Calibration
n Step Action
1 Delete the existing calibration file (if any) from the BTS folder on LMF
laptop from the location C:\wlmf\cdma\bts–#, where # is the BTS
number.
2 To edit the nominal TX BLO, from the Util menu, select Edit > TX
Nominal Offset. In the TX Cal Parameter window, make any necessary
changes to ensure the Tx BLO Nominal Offset (in dB) is correct:
For 800 MHz, the value is 45.0 (dB), OR
For 1900 MHz, the value is 43.0 (dB).
3 Download the data, which includes BLO values, to all the BBXs. From the
Device menu, select Download > Data
3