User's Manual

Test Equipment Set-up68P09258A31–A
Oct 2003
1X SCt 4812T BTS Optimization/ATP
3-57
Supported Test Equipment
CAUTION
To prevent damage to the test equipment, all TX test connections
must be through the directional coupler and in-line attenuator as
shown in the test setup illustrations.
IS–95 A/B Testing
Optimization and ATP testing for IS–95A/B may be performed using
one of the following test sets:
S CyberTest
S Advantest R3465 and HP 437B or Gigatronics Power Meter
S Hewlett–Packard HP 8935
S Hewlett–Packard HP 8921 (W/CDMA and PCS Interface for
1.7/1.9 GHz) and HP 437B or Gigatronics Power Meter
The equipment listed above cannot be used for CDMA 2000 testing.
CDMA2000 1X Operation
Optimization and ATP testing for CDMA2000 1X sites or carriers may
be performed using the following test equipment:
S Advantest R3267 Analyzer with Advantest R3562 Signal Generator
S Agilent E4406A with E4432B Signal Generator
S Agilent 8935 series E6380A communications test set (formerly HP
8935) with option 200 or R2K and with E4432B signal generator for
1X FER
The E4406A/E4432B pair, or the R3267/R3562 pair, should be
connected together using a GPIB cable. In addition, the R3562 and
R3267 should be connected with a serial cable from the Serial I/O to the
Serial I/O. This test equipment is capable of performing tests in both
IS–95 A/B mode and CDMA 2000 mode if the required options are
installed.
S Agilent E7495A communications test set
Optional test equipment
S Spectrum Analyzer (HP8594E) – can be used to perform cable
calibration.
Test Equipment Preparation
See Appendix F for specific steps to prepare each type of test set and
power meter to perform calibration and ATP.
Agilent E7495A communications test set requires additional setup and
preparation. This is described in detail in Appendix F.
3