Read Me First SCE4812T–MC to SCE4812T Optimization/ATP – continued
5/21/04 1X SC4812T–MC BTS Optimization/ATP 1-7
DRAFT
2–carrier, 6–sector configuration (requires 12 measurements) – Use
this procedure to take measurements with both carriers enabled.
Sector Carrier 1 Carrier 2 Sector Carrier 1 Carrier 2
1 BBX-1 1 BBX-7
2 BBX-2 2 BBX-8
3 BBX-9 3 BBX-3
4 BBX-4 4 BBX-10
5 BBX1–11 5 BBX-5
6 BBX1–12 6 BBX-6
Procedure:
1. Enable the following BBXs:
BBX-1 (C1–S1)
BBX-2 (C1–S2)
BBX-4 (C1-S4)
BBX-9 (C2–S3)
BBX-11 (C2-S5)
BBX-12 (C2-S6)
2. Measure TX power from each of all 6 sectors.
3. Disable BBXs.
4. Enable the following BBXs:
BBX-3 (C1–S3)
BBX-5 (C1-S5)
BBX-6 (C1-S6)
BBX-7 (C2–S1)
BBX-8 (C2–S2)
BBX-10 (C2-S4)
5. Measure TX power from each of all 6 sectors.