User Manual

Test Set Calibration – continued
3-74 1X SC4812T–MC BTS Optimization/ATP 5/21/04
DRAFT
Table 3-28: Calibrating TX and Duplexed RX Cables Using Signal Generator and Spectrum Analyzer
n ActionStep
5 Calibration factor = A – B. Example: Cal = –1 dBm – (–53.5 dBm) = 52.5 dB
NOTE
The short cable is used for calibration only. It is not part of the final test setup. After calibration is
completed, do not re-arrange any cables. Use the equipment setup, as is, to ensure test procedures
use the correct calibration factor.
Figure 3-24: Calibrating Test Equipment Setup for TX BLO and TX ATP Tests
(using Signal Generator and Spectrum Analyzer)
50 OHM
TERMINATION
30 DB
DIRECTIONAL
COUPLER
Spectrum
Analyzer
Signal
Generator
A
Spectrum
Analyzer
40W NON–RADIATING
RF LOAD
B
SHORT TEST CABLE
Signal
Generator
THIS WILL BE THE CONNECTION TO THE HP8481A POWER
SENSOR DURING TX BAY LEVEL OFFSET TEST AND TO THE
PCS INTERFACE BOX INPUT PORT DURING TX ATP TESTS.
SHORT
TEST
CABLE
THIS WILL BE THE CONNECTION TO
THE TX PORTS DURING TX BAY LEVEL
OFFSET TEST AND TX ATP TESTS.
CABLE FROM 20 DB @ 20W ATTENUATOR TO THE
PCS INTERFACE OR THE HP8481A POWER SENSOR.
ONE 20DB 20 W IN
LINE ATTENUATOR
FW00293
Non-Duplexed RX Cable Calibration
Table 3-29: Calibrating RX Cables Using a Signal Generator and Spectrum Analyzer
n Step Action
1 Connect a short test cable to the spectrum analyzer and connect the other end to the Signal
Generator.
2 Set signal generator to –10 dBm at the customers RX frequency of 824–849 MHz.
3 Use spectrum analyzer to measure signal generator output (see Figure 3-25, A) and record the
value for A.
4 Connect the test setup, as shown in the lower portion of the diagram to measure the output at the
customers RX frequency of 824–849 MHz. Record the value at point B.
. . . continued on next page
3