User Manual
Test Set Calibration – continued
5/21/04 1X SC4812T–MC BTS Optimization/ATP 3-73
DRAFT
Table 3-27: Cable Calibration
n ActionStep
2 Enter the channel number(s) in the Channels box.
NOTE
Multiple channel numbers must be separated with a
comma and no space (i.e.; 200,800). When two or more
channel numbers are entered, the cables are calibrated for
each channel. Interpolation is accomplished for other
channels as required for TX calibration.
3 In the Cable Calibration pick list select one of the
following:
– TX and RX Cable Cal
– TX Cable Cal
– RX Cable Cal
4 Click OK and follow the direction displayed for each
step. A status report window displays the results of the
cable calibration.
Calibrate Test Cabling Using
Signal Generator & Spectrum
Analyzer
Follow the procedure in Table 3-28 to calibrate the TX/Duplexed RX
cables using a signal generator and spectrum analyzer. Refer to
Figure 3-24, if required. Follow the procedure in Table 3-29 to calibrate
the Non–Duplexed RX cables using the signal generator and spectrum
analyzer. Refer to Figure 3-25, if required.
TX and Duplexed RX Cable Calibration
Table 3-28: Calibrating TX and Duplexed RX Cables Using Signal Generator and Spectrum Analyzer
n Step Action
1 Connect a short test cable between the spectrum analyzer and the signal generator.
2 Set signal generator to 0 dBm at the customer frequency of 869–894 MHz.
3 Use a spectrum analyzer to measure signal generator output (see Figure 3-24, A) and record the
value.
4 Connect the spectrum analyzer’s short cable to point B, (as shown in the lower right portion of the
diagram) to measure cable output at customer frequency of 869–894 MHz. Record the value at
point B.
. . . continued on next page
3