Test Set Calibration – continued
5/21/04 1X SC4812T–MC BTS Optimization/ATP 3-71
DRAFT
Detecting Test Equipment
When Using Agilent E7495A
Be sure that no other equipment is connected to the LMF. The Agilent
E7495A must be connected to the LAN to detect it. Then perform the
procedures described in Appendix F, Table F-1, Table F-2, and
Table F-3.
Calibrating Test Equipment
The calibrate test equipment function zeros the power measurement level
of the test equipment item that is to be used for TX calibration and audit.
If both a power meter and an analyzer are connected, only the power
meter is zeroed.
The Agilent E4406A transmitter tester does not support
power measurement level zeroing. Refer to the Equipment
Calibration section of Appendix F for E4406A calibration.
NOTE
Prerequisites
S LMF computer serial port and test equipment are connected to the
GPIB box.
S Test equipment to be calibrated has been connected correctly for tests
that are to be run.
S Test equipment has been selected in the LMF (Table 3-24 or
Table 3-25).
Calibrating test equipment
Follow the procedure in Table 3-26 to calibrate the test equipment.
Table 3-26: Test Equipment Calibration
n Step Action
1 From the Util menu, select Calibrate Test Equipment
from the pull–down menu. A Directions window is
displayed.
2 Follow the directions provided.
3 Click on Continue to close the Directions window and
start the calibration process. A status report window is
displayed.
4 Click on OK to close the status report window.
Calibrating Cables Overview
The cable calibration function measures the loss (in dB) for the TX and
RX cables that are to be used for testing. A CDMA analyzer is used to
3