User Manual
Test Equipment Set Up – continued
5/21/04 1X SC4812T–MC BTS Optimization/ATP 3-51
DRAFT
IS–95 A/B Testing
Optimization and ATP testing for IS–95A/B may be performed using
one of the following test sets:
S CyberTest
S Hewlett–Packard HP 8935
S Hewlett–Packard HP 8921 and HP 437B or Gigatronics Power Meter
S Advantest R3465 and HP 437B or Gigatronics Power Meter
The equipment listed above cannot be used for CDMA 2000 testing.
CDMA 2000 Testing
IS–95 C is the same as CDMA 2000.
NOTE
Optimization and ATP testing for IS–95A/B and CDMA2000 1X sites or
carriers may be performed using the following test equipment:
S Advantest R3267 Analyzer with Advantest R3562 Signal Generator
S Agilent E4406A with E4432B Signal Generator
S Agilent 8935 series E6380A communications test set (formerly HP
8935) with option 200 or R2K and with E4432B signal generator for
1X FER
S Agilent E7495A communications test set
The E4406A/E4432B pair, or the R3267/R3562 pair, should be
connected together using a GPIB cable. In addition, the R3562 and
R3267 should be connected with a serial cable from the Serial I/O to the
Serial I/O. This test equipment is capable of performing tests in both
IS–95 A/B mode and CDMA 2000 mode if the required options are
installed.
Optional test equipment
S Spectrum Analyzer (HP8594E) – can be used to perform cable
calibration.
Test Equipment Preparation
See Appendix F for specific steps to prepare each type of test set and
power meter to perform calibration and ATP.
The Agilent E7495A communications test set requires additional setup
and preparation. This is described in detail in Appendix F.
Test Equipment Connection
Charts
To use the following charts to identify necessary test equipment
connections, locate the communications system analyzer being used in
the COMMUNICATIONS SYSTEM ANALYZER columns, and read
down the column. Where a dot appears in the column, connect one end
of the test cable to that connector. Follow the horizontal line to locate the
end connection(s), reading up the column to identify the appropriate
equipment and/or BTS connector.
3