User Manual

Test Equipment Set Up
3-50 1X SC4812T–MC BTS Optimization/ATP 5/21/04
DRAFT
Connecting Test Equipment to
the BTS
The following equipment is required to perform optimization:
S LMF
S Test set
S Directional coupler and attenuator
S RF cables and connectors
S Null modem cable (see Figure 3-11)
S GPIB interface box
Refer to Table 3-22 and Table 3-23 for an overview of connections for
test equipment currently supported by the LMF. In addition, see the
following figures:
S Figure 3-15 and Figure 3-16 show the test set connections for TX
calibration.
S Figure 3-18 and Figure 3-19 show test set connections for IS–95 A/B
optimization/ATP tests.
S Figure 3-20 shows test set connections for IS–95 A/B and
CDMA 2000 optimization/ATP tests.
S Figure 3-22 and Figure 3-23 show typical TX and RX ATP setup with
a directional coupler.
Test Equipment GPIB Address
Settings
All test equipment is controlled by the LMF through an IEEE–488/GPIB
bus. To communicate on the bus, each piece of test equipment must have
a GPIB address set which the LMF will recognize. The standard address
settings used by the LMF for the various types of test equipment items
are as follows:
S Signal generator address: 1
S Power meter address: 13
S Communications system analyzer: 18
S Signal generator address: 19
Using the procedures included in the Setting GPIB Addresses section of
Appendix F, verify and, if necessary, change the GPIB address of each
piece of test equipment used to match the above
.
Supported Test Equipment
To prevent damage to the test equipment, all TX test
connections must be through the directional coupler and
in-line attenuator as shown in the test setup illustrations.
CAUTION
3