User Manual

Verifying and Setting GPIB Addresses – continued
5/21/04 1X SC4812T–MC BTS Optimization/ATP F-17
DRAFT
Disconnect other GPIB devices, especially system
controllers, from the system before running the
connectivity software.
NOTE
Table F-13: System Connectivity
Step Action
NOTE
Perform this procedure after test equipment has been allowed to warm–up and stabilize for a
minimum of 60 minutes.
1 Insert HP 83236A Manual Control/System card into memory card slot.
2 Press the [PRESET] pushbutton.
3 Press the Screen Control [TESTS] pushbutton to display the “Tests” Main Menu screen.
4 Position the cursor at Select Procedure Location and select by pressing the cursor control knob.
In the Choices selection box, select Card.
5 Position the cursor at Select Procedure Filename and select by pressing the cursor control knob.
In the Choices selection box, select SYS_CONN.
6 Position the cursor at RUN TEST and select it.
The software will prompt you through the connectivity setup.
7 When the test is complete, position the cursor on STOP TEST and select it; OR press the [K5]
pushbutton.
8 To return to the main menu, press the [K5] pushbutton.
HP PCS Interface Test
Equipment Setup for Manual
Testing
Follow the procedure in Table F-14 to setup the HP PCS Interface Box
for manual testing.
Table F-14: Manual Cable Calibration Test Equipment Setup (using the HP PCS Interface)
n Step Action
NOTE
Verify GPIB controller is turned off.
1 Insert HP83236B Manual Control/System card into the memory card slot.
2 Under Screen Controls, press the [TESTS] push-button to display the TESTS (Main Menu)
screen.
3 Position the cursor at Select Procedure Location and select. In the Choices selection box, select
CARD.
4 Position the cursor at Select Procedure Filename and select. In the Choices selection box, select
MANUAL.
F