User Manual
Verifying and Setting GPIB Addresses – continued
F-12 1X SC4812T–MC BTS Optimization/ATP 5/21/04
DRAFT
Advantest R3465
Communications Test Set GPIB
Address
Follow the steps in Table F-9 and refer to Figure F-9 to verify and, if
necessary, change the GPIB address for the Advantest R3465.
Figure F-9: R3465 Communications Test Set
BNC
“T”
REF UNLOCK
EVEN
SEC/SYNC IN
CDMA
TIME BASE IN
POWER
OFF
ON
REF FW00337
LCL
Shift
Preset
GPIB and others
Vernier Knob
This procedure assumes that the test equipment is set up
and ready for testing.
NOTE
Table F-9: Verify and/or Change Advantest R3465 GPIB Address
Step Action
1 To verify that the GPIB address is set correctly, perform the following procedure:
– Press SHIFT then PRESET.
– Press LCL.
– Press the GPIB and Others CRT menu key to view the current address.
2 If the current GPIB address is not set to 18, perform the following to change it:
– Turn the vernier knob as required to select 18.
– Press the vernier knob to set the address.
3 To return to normal operation, press Shift and Preset.
Motorola CyberTest GPIB
Address
Follow the steps in Table F-10 to verify and, if necessary, change the
GPIB address on the Motorola CyberTest. Changing the GPIB address
requires the following items:
S Motorola CyberTest communications analyzer.
S Computer running Windows 3.1/Windows 95.
F