User Manual
Verifying and Setting GPIB Addresses – continued
5/21/04 1X SC4812T–MC BTS Optimization/ATP F-11
DRAFT
Figure F-8: HP8921A and HP3236A/B
Preset
Cursor Control
Shift
Local
ti-CDMA-WP-00081-v01-ildoc-ftw
This procedure assumes that the test equipment is set up
and ready for testing.
NOTE
Table F-8: Verify and/or Change HP8921A and HP83236A GPIB Addresses
Step Action
1 To verify that the GPIB addresses are set correctly, press Shift and LOCAL on the HP8921A. The
current HP–IB address is displayed at the top of the screen.
NOTE
HP–IB is the same as GPIB.
2 If the current HP–IB address is not set to 18, perform the following to change it:
– Turn the Cursor Control knob to move the cursor to More and press the knob to select the field.
– Turn the Cursor Control knob to move the cursor to I/O Config and press the knob to select the
field.
– Turn the Cursor Control knob to move the cursor to Adrs and press the knob to select the field.
– Turn the Cursor Control knob to change the HP–IB address to 18 and press the knob to set the
address.
– Press Shift and Preset to return to normal operation.
3 To set the HP83236A (or B) PCS Interface GPIB address=19, set the dip switches as follows:
– A1=1, A2=1, A3=0, A4=0, A5=1, HP–IB/Ser = 1
F