User Manual

Verifying and Setting GPIB Addresses – continued
F-6 1X SC4812T–MC BTS Optimization/ATP 5/21/04
DRAFT
Table F-4: Verify and Change Agilent E4406A GPIB Address
Step Action
3b
On the front panel Data Entry keypad, enter the communications system analyzer GPIB address of 18.
The GPIB Address label will change to Enter.
Digits entered with the keypad will replace the current GPIB address in the display.
NOTE
To correct an entry, press the Bk Sp key at the upper right of the keypad to delete one character at a
time.
3c Press the Enter softkey button or the keypad Enter key to set the new GPIB address.
The Config I/O softkey labels will reappear.
The new GPIB address will be displayed under the GPIB Address softkey label.
Agilent E4432B Signal
Generator GPIB Address
Follow the procedure in Table F-5 and refer to Figure F-4 to verify and,
if necessary, change the Agilent E4432B GPIB address.
Figure F-4: Setting Agilent E4432B GPIB Address
Numeric
Keypad
Softkey
Buttons
Softkey Label
Display Area
Active Entry
Area
Backspace
Key
Utility Key
ti-CDMA-WP-00086-v01-ildoc-ftw
F