User Manual
Test Equipment Preparation – continued
5/21/04 1X SC4812T–MC BTS Optimization/ATP F-3
DRAFT
Table F-2: Detecting Agilent E7495A Test Equipment
n ActionStep
3 Check Agilent E7495A option in non–GPIB Test
Equipment and enter its IP number.
4 Click Apply and wait a moment.
5 Click Dismiss.
Power Sensor Calibration
Table F-3 describes the E7495A Power Sensor Calibration.
Table F-3: E7495A Power Sensor Calibration
n Step Action
1 Display the power meter screen.
2 Zero the power meter. Make sure equipment is connected
as shown in Figure F-1.
– Press the Zero softkey.
– Press the Continue softkey.
3 Calibrate the power meter:
– Press Ref CF.
– Enter the reference cal factor, reading it off the label
on the power sensor head.
– Press Calibrate.
– Connect the power sensor (see Figure F-2).
– Press Continue.
– Press Cal Factor.
– Enter the cal factor from the label on the power
sensor head. Select a cal factor that is within the
operating frequency of the BTS being calibrated.
F