User Manual
Troubleshooting: Calibration
6-6 1X SC4812T–MC BTS Optimization/ATP 5/21/04
DRAFT
Bay Level Offset Calibration
Failure
Perform the procedure in Table 6-8 to troubleshoot a BLO calibration
failure.
Only one carrier can be tested at a time. All PAs must be
INS during testing. For the carriers not under test, key one
BBX per carrier to a minimum power level. (Refer to
Table 3-37).
NOTE
Table 6-8: Troubleshooting BLO Calibration Failure
n Step Action
1 Verify the Power Meter is configured correctly (see the test equipment setup section in Chapter 3)
and connection is made to the proper TX port.
2 Verify the parameters in the bts–#.cdf file are set correctly for 800MHz:
Bandclass=0; Freq_Band=8; SSType=8
3 Verify that no PA is in alarm state (flashing red LED).
Reset the PA by pulling the circuit breaker and, after 5 seconds, pushing back in.
4 Re-calibrate the Power Meter and verify it is calibrated correctly with cal factors from the sensor
head.
5 Verify the GPIB adapter is not locked up.
Under normal conditions, only two green LEDs must be ‘ON’ (Power and Ready).
If any other LED is continuously ‘ON’, power-cycle (turn power off and on) the GPIB Box and
retry.
6 Verify the sensor head is functioning properly by checking it with the 1 mW (0 dBm) Power Ref
signal.
7 If communication between the LMF and Power Meter is operatonal, the Meter display will show
“RES”.
Cannot Load BLO
For Load BLO failures see Table 6-7.
6