User Manual

Automated Acceptance Test Procedures – TX & RX – continued
4-6 1X SC4812T–MC BTS Optimization/ATP 5/21/04
DRAFT
Table 4-1: ATP Test Procedure
n ActionStep
NOTE
Single–sided BLO is only used when checking non–redundant transceivers.
7 If applicable, select a test pattern from the Test Pattern pick list.
NOTE
S Selecting Pilot (default) performs tests using only a pilot signal.
S Selecting Standard performs tests using pilot, synch, paging and 6 traffic channels. This
requires an MCC to be selected.
S Selecting CDFPilot performs tests using only a pilot signal, however, the gain for the channel
elements is specified in the CDF file.
S Selecting CDF performs tests using pilot, synch, paging and 6 traffic channels, however, the
gain for the channel elements is specified in the CDF file.
8 Click on the OK button.
The status report window and a Directions pop-up are displayed.
9 Follow the cable connection directions as they are displayed.
The test results are displayed in the status report window.
10 Click on Save Results or Dismiss.
NOTE
If Dismiss is used, the test results will not be saved in the test report file.
11 Refer to Steps NO TAG through sub-step NO TAG of Table 3-37 to dekey.
4