User's Manual

Short Duration Battery Cabling
JAN 2002
6-21
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
DRAFT
Objective
The objective of this procedure is to attach the short duration battery
cable.
Battery Cable
The battery cable is part of the battery assembly. The same type
connector is used for the short duration battery and DC input cables.
Procedure to Install Short
Duration Battery Cable to the
Unit
Use the following procedure in Table 6-15 to attach the short duration
battery (DC input) cable to the DC input connector. Refer to
Figure 6-14. The cable should be connected before the solar cover is
attached.
The short duration battery should not be opened under any
circumstances. No wire termination is required by the user except
connection to the BTS, with the provided connector.
Table 6-15: Procedure to Install Short Duration Battery Cable to Unit
Step Action
1 Ensure that the ground wire has a connection to unit and the Master Ground Bus (also called
Master Ground Plate).
2 Verify that the DC power breaker is open. The white collar on the breaker is visible when it is
open.
3 Place the round, black connector of the DC input cable onto the DC input connector on the BTS.
Refer to Figure 6-14. Turn the cable connector to align its key.
4 Hand tighten the connector (a clicking sound is heard, this is normal). When the red line on the
connector on the unit is covered, connection is complete.