User's Manual
Subscriber Unit (SU) Installation and Cabling – continued
DRAFT
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
JAN 2002
6-16
Procedure to Install SU Box
Table 6-11 gives the procedure to install the SU box on a MicroCell unit.
You must install one SU on each unit at the BTS.
Table 6-11: Procedure to Install the SU Box
Step Action
1 Attach one end of the Y–Ground cable (cable L) to the SU. Use one M6x19 tamper–resistant
screw. Torque to 5.0 N–m.
NOTE
If unit is not equipped with a Site I/O, then one end of the Y–ground cable will hang loose.
2 Position the SU as shown in Figure 6-10.
3 Insert the oval protrusion of the SU onto the slotted hole on the cooling fins.
4 Use a torque driver and a T30 TORX bit to tighten the tamper–resistant screw. Tighten to 5.0
N–m.
Figure 6-10: Attaching Subscriber Unit (SU) to Unit
INSERT OVAL
PROTRUSION ONTO
SLOTTED HOLE OF
COOLING FINS
MASTER GROUND
CABLE (CABLE Y)
Y–GROUND CABLE
(CABLE L)
TAMPER–RESISTANT
SCREW
6