User's Manual

Attaching Unit to Mounting Bracket
DRAFT
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
JAN 2002
6-8
Objective
The objective of this procedure is to attach the unit to the mounting
bracket. This procedure applies to mounting brackets that are attached to
a rack, wall, or pole.
Background
The unit attaches to the mounting bracket with two (2) M6 screws and
the provided pin or a customersupplied padlock.
The handles should be mounted to the unit before
mounting the unit to the bracket. The handles should be
used to lift the unit onto the bracket. If the solar cover is to
be used, the back cover must be attached prior to mounting
the unit. Remove the handles once the unit has been
secured to the mounting bracket.
NOTE
Required Tools and Equipment
The following tools and equipment are required to attach the unit to the
mounting bracket:
Torque driver wrench, 1/4in. hex female drive, 010 NM
T30 Torx tamper bit
Two M6X19 screws (Motorola Part Number 0387541C03)
Procedure to Attach the Unit to
the Mounting Bracket
Follow the procedure in Table 6-4 to attach the unit to the mounting
bracket. Refer to Figure 6-6.
Use caution when resting the MicroCell unit on the hooks
of the mounting bracket. Do not leave unit supported by
hooks only.
CAUTION
Table 6-4: Procedure to Attach the Unit to the Mounting Bracket
Step Action
1 Lift the unit using the installation handles and place it on the mounting bracket by aligning the
brackets upper arms into the rectangular cutouts in the heatsink. The unit will need to be raised
up slightly so that the lower bracket flange does not contact the units lower surface.
2 Use a T30 Torx tamper bit to start, but not tighten, both screws in the location shown in
Figure 6-6.
. . . continued on next page