User's Manual

Cable Descriptions continued
JAN 2002
4-3
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
DRAFT
Table 4-1: Cable Descriptions and Part Numbers
Cable DescriptionPart NumberQty.
S 14 3087854C02 AC input power cable. 14 AWG. 5m. Designed for 120240 VAC
power input. Cable has Deutsche connector on both ends.
T 1 Customer
Supplied
AC Input power cable. 1014 AWG, 90C wire. Designed for
120240 VAC.
U 1 3087854C04 DC input cable, 14 and 22 AWG, 5 m, is designed for 20 to 30 VDC
power input.
V 1 Customer
Supplied
Phone (Modem) cable. 2224 AWG solid copper twisted pair.
W 13 Customer
Supplied
Span Line Daisy Chain cable.
X 111
3086039H18 RGPS Synchronization cable (part of kit SGKN4351A).
3086039H19 RGPS Synchronization cable (part of kit SGKN4352A).
Y 1 Customer
Supplied
Master Ground Cable, 6 -AWG, insulated copper wire. Used for both
Primary Surge Suppressor and nonPrimary Surge Suppressor
installations.
Z 1 3088116C01 Site I/O Cable Extender. Required for use in a BTS not equipped
with the Primary Surge Suppressor.
*Quantity of cables depends upon system configuration. Refer to Motorola Kits for MultiUnit
Installations for more information.
Motorola Kits for MultiUnit
Logical BTS Installations
Table 4-2 through Table 4-9 gives the Motorola Kit numbers, cable
descriptions and part numbers for the Motorola kits required to perform
a multiunit logical BTS installation. Several kits are available
depending upon the carrier installation.
Table 4-2: MicroCell Expansion Kit for Units 1 to 2 Short MIB A (Cubicle) T448B
Cable Qty. Motorola Part
Number
Description
n/a 2 5882106P01 50 Ohm Antenna Terminator
A 1 3087701C02 Ground cable, 8 -AWG, insulated copper wire. Requires one ring lug
connector.
K 1 3087707C09 MIB A cable (short, 1m; micro)
4