User's Manual

Cable Descriptions
DRAFT
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
JAN 2002
4-2
Cable Descriptions and Part
Numbers
Table 4-1 gives the cable descriptions and part numbers for the cables
used to install the BTS. The following cables are necessary for sites
equipped with the customersupplied Site I/O Interface and the Primary
Surge Suppressor.
Table 4-1: Cable Descriptions and Part Numbers
Cable Qty. Part Number Description
A 1 3087701C02 Ground cable, 8 -AWG, insulated copper wire. Requires one ring lug
connector. Used for Primary Surge Suppressor Installation.
B 14 3087701C01 Ground cable. Installed between Site I/O Junction Box and Mounting
Bracket.
C 18 Customer
Supplied
Antenna cable, 50Ohm coaxial terminated with at least one male,
Ntype connector.
D 26 Customer
Supplied
Antenna cable, terminated with 2 male Ntype connectors
E 1* 3087707C03 MIB A cable (current, 2m; micro) (part of kit T448H, T448G and
T448A)
F 1* 3087707C04 MIB B cable (current, 2m) (part of kit T448AR, T448AY, and T448H)
G 2* 3087707C05 MIB C cable (current, 2m) (part of kit T448H)
I 1* 3087707C07 MIB B cable (long, 5m) (part of kit T448AS, T448AZ, and T448G)
J 2* 3087707C08 MIB C cable (long, 5m) (part of kit T448G)
K 1* 3087707C09 MIB A cable (short, 1m; micro) (part of kit T448B)
L 14 3087701C04 YGround cable (for Site I/O and external SU)
M 1
3086039H11 RGPS cable, 125 ft.
3086039H12 RGPS cable, 250 ft.
3086039H13 RGPS cable, 500 ft.
3086039H14 RGPS cable, 1000 ft.
3086039H15 RGPS cable, 2000 ft.
N 1 Customer
Supplied
Span cable. 2224 AWG solid copper twisted pair.
O 1 Customer
Supplied
Customer Input cable. 2224 AWG solid copper twisted pair.
P 14 3088120C03 SU RF cable
Q 1 SU Digital Cable
. . . continued on next page