User's Manual
Subscriber Unit (SU) Test and Setup – continued
JAN 2002
7-71
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
DRAFT
Procedure to Program SU NAM
Parameters
Follow the instructions in Table 7-42 to program the SU NAM
parameters.
Table 7-42: Procedure to Program the SU NAM Parameters
Step Action
1 Enter the following command at the sc300’x–1> prompt to turn the power to the SU on:
su power on
2 Enter the following command at the sc300’x–1> prompt to view the NAM parameters stored
in the SU:
su nam show
The system will display the following typical output:
sc300’x–1>
su nam show
COMMAND ACCEPTED: su nam show
SU NAM CONFIG
–––––––––––––––––––––––
Phone Number 8476324677
Station Class Mark 34
Access Overload Code 0
Si d 8
Security Code 48
Lock Code 123
Slot Cycle Index 2
System Id 1
Network Id 65535
IMSI 11 & 12 11
IMSI MCC 111
CDMA Pri Channel A 76
CDMA Pri Channel B 76
CDMA Sec Channel A 872
CDMA Sec Channel B 872
NOTE
The NAM values shown above are for example only. You must enter site–specific NAM
parameter values into the following commands.
3 Enter the following command at the sc300’x–1> prompt to program the Mobile Phone
Number:
su nam min <phone number>
4 Enter the following command at the sc300’x–1> prompt to program the Access Overload
Code:
su nam aoc <access overload code>
5 Enter the following command at the sc300’x–1> prompt to program the Slot Cycle Index:
su nam si <slot cycle index>
. . . continued on next page
7