User's Manual
Create CAL File
JAN 2002
7-65
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
DRAFT
Objective
Use this procedure to create a CAL file for the Calibration audit. You
must do this procedure before the RF path audit.
Background
The Create CAL File function gets the BLO data from the MAWI and
creates/updates the CAL file for the BTS. If a CAL file does not exist, a
new one is created. If a CAL file already exists, it is updated. The BTS
is calibrated at the factory and normally does not require calibration after
installation, so you must use the Create CAL File function to create a
CAL file since TX calibration is not performed.
The Create CAL File function only applies to selected
(highlighted) MAWIs.
NOTE
The CBSC does not require a calibration file for operation
of an SC300 BTS.
NOTE
The user is not encouraged to edit the CAL file as this
action can cause interface problems between the BTS and
the LMF. To manually edit the CAL file, you must first
logout of the BTS. If you manually edit the CAL file and
then use the Create CAL File function, the edited
information is lost.
NOTE
Prerequisites
The following must be done before you run this test:
The MAWI has the correct code load and data load.
The MAWI is INS.
The LMF is logged on to the BTS.
7