User's Manual

Test Equipment Selection continued
DRAFT
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
JAN 2002
7-58
Selecting Test Equipment
Automatically or Manually
Use LMF Options from the Tools>Options menu list to select test
equipment automatically (using the autodetect feature) or manually.
A Serial Connection and a Network Connection tab are provided for
test equipment selection. The Serial Connection tab is used when the
test equipment items are connected directly to the LMF computer via a
GPIB box (normal setup). The Network Connection tab is used when
the test equipment is to be connected remotely via a network connection.
Procedure to Manually Select
Test Equipment in a Serial
Connection Tab
Test equipment can be manually specified before, or after, the test
equipment is connected. The LMF does not check to see if the test
equipment is actually detected for manual specification. Follow the
procedure in Table 7-36 to select test equipment manually.
Table 7-36: Procedure to Manually Select Test Equipment in a Serial Connection Tab
Step Action
1 Select Tools>Options. The LMF Options window appears.
2 Click on the Serial Connection tab (if not in the forefront).
3 Select the correct serial port in the COMM Port pick list (normally COM1).
4 Click on the Manual Specification button (if not enabled).
5 Click on the check box corresponding to the test item(s) to be used.
6 Type the GPIB address in the corresponding GPIB address box (the default address is 1).
Recommended Addresses
1 = R3562 Test Source
13 = Power Meter
18 = CDMA Analyzer
7 Click on Apply (the button darkens until the selection has been committed).
NOTE
With manual selection, the LMF does not detect the test equipment to see if it is connected and
communicating with the LMF.
8 Click on Dismiss to close the test equipment window.