User's Manual
Test Equipment Calibration – continued
DRAFT
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
JAN 2002
7-54
Procedure to Calibrate Agilent
E4406A
Refer to Figure 7-27 and follow the procedure in Table 7-32 to perform
the Agilent E4406A self–alignment (calibration).
Table 7-32: Perform Agilent E4406A Self–alignment (Calibration)
Step Action
1 In the SYSTEM section of the instrument front panel, press the System key.
– The softkey labels displayed on the right side of the instrument screen will change.
2 Press the Alignments softkey button to the right of the instrument screen.
– The softkey labels will change.
3 Press the Align All Now softkey button.
– All other instrument functions will be suspended during the alignment.
– The display will change to show progress and results of the alignments performed.
– The alignment will take less than one minute.
Figure 7-27: Performing Agilent E4406A Self–alignment (Calibration)
System
Key
Softkey
Buttons
Softkey Label
Display Area
7