User's Manual
Test Equipment Calibration – continued
DRAFT
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
JAN 2002
7-52
Procedure to Calibrate Test
Equipment
The calibrate test equipment function zeros the power measurement level
of the test equipment item that is to be used for TX calibration and audit.
If both a power meter and an analyzer are connected, only the power
meter is zeroed.
Use the Calibrate Test Equipment menu item from the Util menu to
calibrate test equipment. The test equipment must be selected before
calibration can begin. Follow the procedure in Table 7-29 to calibrate the
test equipment.
Prerequisites
Ensure the following prerequisites have been met before proceeding:
Test equipment to be calibrated has been connected correctly for tests
that are to be run.
Test equipment has been selected.
Table 7-29: Procedure to Calibrate Test Equipment
Step Action
1 From the Util menu, select Calibrate Test Equipment.
A Directions window is displayed.
2 Follow the directions provided.
3 Click on Continue to close the Directions window.
A status report window is displayed.
4 Click on OK to close the status report window.
Calibration Without the LMF
Several test equipment items used in the optimization process require
pre–calibration actions or calibration verification which are not
supported by the LMF. Procedures to perform these activities for the
applicable test equipment items are covered in this section.
7