User's Manual

GPIB Addresses continued
JAN 2002
7-45
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
DRAFT
RS232 GPIB Interface Box
Ensure that the RS232 GPIB interface box dip switches are set as shown
in Figure 7-22.
RS232GPIB
INTERFACE BOX
S MODE
DATA FORMAT
BAUD RATE
GPIB ADRS
ON
DIP SWITCH SETTINGS
G MODE
Figure 7-22: RS232 GPIB Interface Box
Verify and Set Advantest R3267
GPIB Address
Perform the procedure in Table 7-26 and refer to Figure 7-23 to verify
and, if necessary, change the Advantest R3267 spectrum analyzer GPIB
address.
Table 7-26: Verify and Change Advantest R3267 GPIB Address
Step Action
1 If the REMOTE LED is lighted, press the LCL key.
The LED extinguishes.
2 Press the CONFIG key.
The CONFIG softkey labels will appear in the softkey label display area of the instrument
display.
The current GPIB address will be displayed below the GPIB Address softkey label.
3 If the current GPIP address is not set to 18, perform the following to change it:
3a Press the GPIB Address softkey.
A GPIB Address entry window will open in the instrument display showing the current GPIB
address.
. . . continued on next page
7