User's Manual
GPIB Addresses – continued
JAN 2002
7-45
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
DRAFT
RS232 GPIB Interface Box
Ensure that the RS232 GPIB interface box dip switches are set as shown
in Figure 7-22.
RS232–GPIB
INTERFACE BOX
S MODE
DATA FORMAT
BAUD RATE
GPIB ADRS
ON
DIP SWITCH SETTINGS
G MODE
Figure 7-22: RS232 GPIB Interface Box
Verify and Set Advantest R3267
GPIB Address
Perform the procedure in Table 7-26 and refer to Figure 7-23 to verify
and, if necessary, change the Advantest R3267 spectrum analyzer GPIB
address.
Table 7-26: Verify and Change Advantest R3267 GPIB Address
Step Action
1 If the REMOTE LED is lighted, press the LCL key.
– The LED extinguishes.
2 Press the CONFIG key.
– The CONFIG softkey labels will appear in the softkey label display area of the instrument
display.
– The current GPIB address will be displayed below the GPIB Address softkey label.
3 If the current GPIP address is not set to 18, perform the following to change it:
3a Press the GPIB Address softkey.
– A GPIB Address entry window will open in the instrument display showing the current GPIB
address.
. . . continued on next page