User's Manual
GPIB Addresses – continued
JAN 2002
7-41
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
DRAFT
MENU ENTER
ARROW
KEYS
1
Figure 7-18: Gigatronics 8541C Power Meter Detail
Verify and Set Motorola
CyberTest GPIB Address
Follow the steps in Table 7-22 to verify and, if necessary, change the
GPIB address on the Motorola CyberTest. Changing the GPIB address
requires the following items:
Motorola CyberTest communications analyzer.
Computer running Windows 3.1/Windows 95.
Motorola CyberTAME software program “TAME”.
Parallel printer port cable (shipped with CyberTest).
Table 7-22: Verify and/or Change Motorola CyberTest GPIB Address
Step Action
1 On the LMF desktop, locate the CyberTAME icon. Double click on the icon to run the CyberTAME
application.
2 In the CyberTAME window taskbar, under Special, select IEEE.488.2.
3 CyberTAME software will query the CyberTest Analyzer for its current GPIB address. It will then
open the IEEE 488.2 dialog box. If the current GPIB address is not 18, perform the following steps to
change it:
– Use the up or down increment arrows, or double–click in the field and type the number.
– Click on the OK button. The system will write and save the new address to the CyberTest via the
parallel port.
NOTE
Repeat steps 2 and 3 to verify that the address was set. The new address should now appear in the
IEEE 488.2 dialog box Address field.
7