User's Manual

Shut Down & Restore BTS Signaling continued
DRAFT
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
JAN 2002
8-6
Table 8-2: Procedure to Shut Down Signaling Functions
Step Action
4 View the status of the sector signaling redirect parameters to verify that the sector is ready for
maintenance.
omc000000>display sector<bts#><sector#> redirect
Ensure that the values in the system display response match the values input in step 3 (see
example below).
Access Overload Class Redirect Flags ROTATE
CARRIER ID RETURN 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 TIMER RECORD EXP IGNORE SYS
(btssectorcarrier) IF FAIL 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 (SEC) TYPE SID CDMA ORDERING
–––––––––––––––––––– ––––––– ––––– –––– –––– ––– ––––––––
CARRIER111 N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y 4 4 13 Y CUSTOM
5 If you entered 2 for <recordtype> in step 3, go to step 6.
If you entered 1 for <recordtype> in step 3, go to step 9.
6
* IMPORTANT
Record the values shown in the following system display response. These values will be used to
answer the prompts for the EDIT SECTOR REDIRECT2 command when restoring signaling
operations at the end of the replacement procedure.
View the status of the BTS signaling redirect parameters for all carriers equipped for the BTS.
Enter the following command at the prompt:
omc000000>display sector<bts#><sector#> redirect2
omc 000000>
display sector
<bts#> <sector#>
redirect2
Ensure that the values in the system display response match the values input in step 3.
Observe the following typical system output:
Access Overload Class Redirect Flags
CARRIER ID EXP BAND 123456 789101112131415
(btssectorcarrier) NID CLASS
–––––––––––––––––––– –––– ––––– –––––––––––––––––––––––––––––––––––––––––––––––––––––––
CARRIER111 65535 AMPS –––––– ––––––––
. . . continued on next page
8