Service Manual

GSM-205-323
Specifications
31st Oct 01
Technical Description: Horizon
macro
indoor
68P02902W07-B
CONTROLLED INTRODUCTION
Tech. 1–9
Specifications
Overview of
specifications
All Horizon
macro
specifications are included in this section.
Software
requirements
The GSM/EGSM900 and DCS1800 BTSs require software release GSR4 (or
later) in the network.
The GSM850 and PCS1900 BTSs require software release GSR5.1 (or later) in
the network.
Approval and
safety
Table 1-2 lists the specifications with which the Horizon
macro
indoor complies.
Table 1-2 Horizon
macro
specification compliance
GSM/EGSM900 & DCS1800 GSM850 & PCS1900
Type
l
ETS 301 502
approval
CFR47 Part 2
CFR47 Part 22 (850 only)
CFR47 Part 24 (1900 only)
EMC EN301 489-8
CFR 47 Part 2 and 15
CFR47 Part 22 (850 only)
CFR47 Part 24 (1900 only)
Safety EN 60215, IEC 60215, EN 60950, IEC 950,
CSA 22.2 No. 950, UL 1950
Environmental
limits
Table 1-3 lists the operating and storage environmental limits.
Table 1-3 Environmental limits
Environment Temperature Relative Humidity
Operating –5 C to + 45 C. 5% to 100% relative humidity, not to
exceed 0.029 g water / m
3
dry air.
Storage –45 C to +70 C. 8% to 100% relative humidity, not to
exceed 0.029 g water / m
3
dry air.
NOTE This specification is valid up to 3 km altitude,
corresponding to an atmospheric pressure range of 648 to
1048 millibars.