Service Manual

GSM-205-423
BTS architectures and interoperability
31st Oct 01
Inst. 3–10
Installation & Configuration: Horizon
macro
indoor
CONTROLLED INTRODUCTION
68P02902W08-B
M-Cell
6
and
Horizon
macro
hardware
equivalents
Table 3-2 shows the RF hardware equivalents for the Horizon
macro
and M-Cell
6
BTSs.
Table 3-2 RF hardware equivalents for Horizon
macro
/M-Cell
6
Horizon
macro
900/1800
M-Cell 900 M-Cell 1800
DCF CBF + duplexer Hybrid + duplexer
DDF 3- input CBF
*
+
duplexer
2 x hybrid + dup/BPF
HCU Hybrid Hybrid
Feedthrough plate Non-hybrid (no equivalent)
TDF TBF + duplexer 2 x dup/BPF
CCB master CCB master CCB master
CCB extender CCB extender CCB extender
SURF 3 x DLNB + IADU 3 x LNA
Split Sector Cable Rx Extender (no equivalent)
*
3-input CBF contains only one internal 50 ohm load.
Further
configuration
information
Provided the functional guidelines described in this chapter are followed, the
steps involved in upgrading an existing site with mixed equipment are
essentially the same as with a conventional upgrade:
Determine the number of additional carriers required in the upgraded site.
Based on the required site configuration (for example, 4/4/4), use the
functional guidelines provided in this chapter to decide the most effective
hardware configuration for the additional cabinet(s).
Special upgrade kits are available for specified configurations.
Configuration diagrams and product ordering help are available from the
Motorola local office.