Service Manual
GSM-205-423
Site requirements and considerations
31st Oct 01
Inst. 1–8
Installation & Configuration: Horizon
macro
indoor
CONTROLLED INTRODUCTION
68P02902W08-B
Cabinet weights
The weights of the fully populated cabinets are listed in Table 1-4.
CAUTION
Consider future expansion. Another cabinet may be added
by stacking on top of the existing cabinet. This, if used
with stacking units on both, each with CCBs, and
associated cables, could result in a total weight of 280 kg.
Ensure floor is capable of supporting this weight.
Table 1-4 Main indoor cabinet weights (with six transceivers)
Cabinet with plinth and
hood
Cabinet with plinth, stacking bracket and
CCB
115 kg 130 kg
Torque values
Use the torque values listed in Table 1-5 during installation (see NOTE for M12).
Table 1-5 Torque values for all cabinet screws/bolts and RF connectors
Size of
screw/bolt
M4 M6 M8 M10 SMA N-type 7/16
Torque value 2.2 Nm 3.4 Nm 5 Nm 10 Nm 1 Nm 3.4 Nm 25 Nm
NOTE Torque values used with M12 anchor bolts will depend on
the anchor bolt manufacturer. Check manufacturers data
for correct values.