Service Manual
GSM-204-323
Top section
31st Oct 01
Tech. 2–8
Technical Description: Horizon
macro
outdoor
CONTROLLED INTRODUCTION
68P02902W02-A
Earth plates
An earth/connector plate is fitted to the cable entry side of the cabinet. The
earth plate is supplied with:
Three N-type to 7/16 bulkhead cables, (for connection between earth plate
and SURF module).
Three 7/16 to 7/16 bulkhead cables, (for connection between earth plate
and Tx block ANT connector).
Provision to fit up to three extra long RF cables, (for connection between
cabinets in multiple cabinet site configurations).
– Rx0B, Rx1B and Rx2B on the right side plate.
– Rx0A, Rx 1A and Rx2A on the left side plate.
The cabinet earth plate has the following functions:
Provision of the main cabinet earth connection.
Provision of a connection point for customer antennas.
Weatherproof pass-through for: ac power, external battery and customer
communications cables.
Figure 2-6 shows the layout of the right earth/connector plate viewed from inside
the top section (the layout for the left plate is a mirror image of this). The six
permanently connected RF cables are omitted for clarity.
TX 0
AC IN
DC IN
RX 1B
RX 0B
RX 2A
RX 1A
RX 0A
TX 1
TX 2
RX 2B
EARTH STUD
COMMS
Figure 2-6 Cable entry side earth plate