Service Manual

GSM-204-323
Top section
31st Oct 01
Tech. 2–6
Technical Description: Horizon
macro
outdoor
CONTROLLED INTRODUCTION
68P02902W02-A
Top section
Top section
description
The top section provides:
A basket to hold up to three Tx blocks. This includes three holes to enable
connection of CTU Tx cables to the underside of each Tx block. The holes
also allow cooling of the Tx blocks from underneath.
A slot for insertion of the SURF module.
A location hole for the interface panel. The interface panel is positioned
into the top section from underneath and fixed from the top.
Cable holes for fibre optic extension cables (from the MCUF FMUX to an
FMUX of another cabinet), and alarm cables.
Earth plates fitted to the ends of the top wrap. The earth plate contains the
RF cabling, which allows the connection of external antennas to internal
RF cabling, at the cable entry side. A blank plate or expansion plate is
fitted at the opposite end of the top wrap.
A panel for the power supply unit dc output and external battery cables.
A location hole for the number 1 ac distribution box (the power supply
input connection and switching). The number 1 ac distribution box slots
into the top section from underneath.
The top section also houses krone blocks and an ac outlet socket.